Skip to main content

Table 2 Intra-rater repeatability and limits of agreement of CBCT scan measures

From: Cone beam computed tomography for the assessment of linear scleroderma of the face

   Soft Tissue Thickness Total Thickness
Anatomic Section Radial Measure ICC 95% CI p ICC 95% CI p
Mandibular Condyle (MC) Right 30° 0.994 (0.984–0.997) 0.000 0.996 (0.989–0.998) 0.000
Right 60° 0.921 (0.814–0.967) 0.000 0.989 (0.972–0.995) 0.000
Left 30° 0.984 (0.959–0.993) 0.000 0.992 (0.981–0.996) 0.000
Left 60° 0.903 (0.774–0.96) 0.000 0.978 (0.945–0.991) 0.000
Maxillary Sinus (MS) Right 30° 0.969 (0.925–0.987) 0.000 0.981 (0.953–0.992) 0.000
Right 60° 0.968 (0.922–0.987) 0.000 0.965 (0.916–0.986) 0.000
Left 30° 0.864 (0.694–0.943) 0.000 0.989 (0.972–0.995) 0.000
Left 60° 0.973 (0.935–0.989) 0.000 0.962 (0.909–0.984) 0.000
Mandibular Foramen (MF) Right 30° 0.940 (0.856–0.975) 0.000 0.993 (0.982–0.997) 0.000
Right 60° 0.967 (0.919–0.986) 0.000 0.990 (0.974–0.995) 0.000
Left 30° 0.939 (0.855–0.975) 0.000 0.857 (0.679–0.94) 0.000
Left 60° 0.921 (0.813–0.967) 0.000 0.968 (0.922–0.987) 0.000